Seal Support System

Seal Support System

API PLAN 76

API PLAN 76

Product Description

P.No. Description
F1
Flange
F2
Blind Flange
V1
Two way manifold valve
V2
Ball Vavle
G1
Pressure gauge
G2
Pressure Transmitter/Switch
G3
Orifice-Plate
N1
Vent
N2
Drain

  • It is used to collect leakage for non- condensing liquid and route to flare line.
  • This plan is used if the pumped fluid does not condense at ambient temperature
  • They are used on arrangement 2 unpressurised dual seals, which also utilises a dry containment seal and where leakage from the inner seal is gas or vapour.

  • Least expensive
  • Ease of maintenance
  • Leakage is easily routed to vapor recovery system or flare system
  • Simples piping

  • Tubing or piping shall be minimum ½” and shall rise continuously upward from the CSV Connection.
  • Leakage from the inner seal is restricted from escape by the containment seal and goes out of containment seal vent (CSV) Connection
  • An orifice plate in the piping restricts flow such that or high leakage of the inner seal will cause a pressure increase and trigger the pressure transmitter to alarm at 0.7 bar (g)
  • A drain connection on the piping may be u sed to inject nitrogen or other gas for the purpose of testing the containment seal.